SuperMATCH Thunder/24 VL
Release Notes
23 April 1993
These release notes contain the latest information about operating your
new Thunder/24 for Microsoft Windows graphics card and software.
-------- Release Notes ---------
1. Requirements
The Thunder/24 drivers require a 80386 based CPU or better, and are
fully supported only in Windows 3.1 386 Enhanced mode. SuperMac
STRONGLY recommends you make the inexpensive upgrade to Windows 3.1.
2. Unnamed floppy prompt
If you attempt to install the Thunder/24 software from your B: floppy,
you will see the prompt "Please insert the .", due to a bug in the
Windows SETUP program. Type "B:\" (or the name of the disk drive
holding the Thunder/24 install disk), then click OK.
3. Third-party "shell" programs
If you are using a third-party shell program, such as the Norton Desktop
for Windows, and you experience problems while installing Thunder/24
software, refer to the detailed section later in this file.
4. Applications with difficulties at 24 bits
- The Windows Program Manager will cause errors if you attempt to add the
applications to a large group. See the detailed section later in this
file.
- The Microsoft Visual C++ setup program attempts to create a large group
and will issue two errors. See the detailed section later in this file.
- The "Aquatic Realm" and "Swan Lake" screen saver modules in After Dark
2.0 display strange bitmaps on devices with 24 bits of color depth.
Release 2.0a of After Dark solves this problem. Contact Berkeley
Systems Technical Support at 1-800-877-5535 for this upgrade.
- You shouldn't use full-screen mode in Microsoft MediaPlayer on non-VGA
devices. See the detailed section later in this file.
5. Compaq Prosignia with motherboard SCSI
If you intend to install your Thunder/24 in a Compaq Prosignia system
using a SCSI disk and the on-board SCSI controller, you need to take
an additional step after installing your Thunder/24 but before actually
using the board. Refer to the detailed section later in this file.
==========================
-------- Details ---------
==========================
This file contains notes and information relating to the Windows driver
installation and usage which might not have made it into the release
documentation.
1. Restrictions
---------------
The Thunder/24 drivers require an 80386 CPU or better, and are fully
supported only in Windows 3.1 386 Enhanced mode. Our experience has shown
that the driver operates correctly in Windows Standard mode only if an
extended memory manager (such as EMM386 or QEMM) is NOT used. Thunder/24
will not operate at all in Windows 3.0 Real mode, and neither should you.
Ordinarily, this does not present a problem. Most 386 users use Enhanced
mode. However, when you perform an initial Windows installation, you must
select a VGA device as your initial graphics adapter when performing an
initial Windows installation. Then, once Windows has been installed, you
may use the Thunder/24 Setup utility to change to the Thunder/24 adapter.
2. Windows 3.0
--------------
SuperMac does not support operation of the Thunder/24 VL card and driver
under Windows 3.0.
3. Installation Notes
---------------------
. Locating the frame buffer window
Thunder/24 VL needs a 16MB window in your memory space to access its
frame buffer. The frame buffer can be located at any 16MB boundary in
the address space. The installation program will scan your address space
in an attempt to locate available locations. In our experience, the
install program rarely has trouble finding a free location; further,
almost any address higher than your physical memory will usually work.
Because of the nature of the VL bus, however, the installation program
is not always able to locate a free spot, and will occasionally diagnose
as "free" a location which has some other device. The following
suggestions will assist you in installing the device.
There are relatively few devices which live in the very high address
space. In general, you can choose almost any location above your
physical RAM. F000 0000 through FF00 0000 are good choices. If these
are unsuccessful, try in this order, 7F00 0000, then 3F00 0000, then
1F00 0000, then 0F00 0000.
. Unnamed floppy prompt
Because of a bug in the Windows SETUP utility, if you are installing
Thunder/24 from your B: floppy, you might be prompted with the
particularly unfriendly message "Please insert the ." If you receive
this prompt, type in "B:\", or the path to the floppy disk drive
holding the Thunder/24 install disk if you are using a different
drive.
. Third-party "Shell" Programs
The Thunder/24 installation and setup program communicates with the
Windows Program Manager to install the Thunder/24 group and program
icons. Some third-party shells, such as Norton's Desktop for Windows,
do not fully comply with the Program Manager DDE interface, and will
produce a system error during the Thunder/24 installation.
To work around this problem, either change the SHELL line in your
SYSTEM.INI file to read "SHELL=PROGMAN.EXE" and restart Windows, or
launch PROGMAN.EXE from your preferred shell. Then, restart the
Thunder/24 installation.
4. Applications with difficulty at 24 bits per pixel
----------------------------------------------------
Some applications have difficulty operating on a true-color device with 24
bits per pixel. Here are some of the applications which are known to have
difficulty.
. Program Manager
All of the bitmaps for all of the icons within a Program Manager group
must fit within a single 64K segment. Because of this, at 24 bits per
pixel a single group can hold at most 19 icons. Attempting to add the
20th icon to a group results in a message box indicating "Insufficient
Memory to complete the operation." The only solution to this is to
split the group into two smaller groups.
In Windows 3.0, adding a 20th icon to a group crashes Windows. Here is
yet another good reason to upgrade to 3.1.
. Microsoft Visual C++
As one of the last steps in its setup process, Microsoft Visual C++
creates a program group with 22 icons. Because of the Program Manager
limitation described above, the addition of the last two icons will
generate errors. Microsoft is aware of this problem and will be issuing
a corrective update.
In the interim, one solution is to create another group by hand
called "Visual C++ Doc", then move (using drag-and-drop) all the
documentation related icons to this new group. Then you may add the two
icons which fail: MFCNOTES.HLP and MFCSAMP.HLP, both in the MSVC\HELP
directory.
. Berkeley Systems After Dark 2.0
The "Aquatic Realm" and "Swan Lake" screen saver modules in After Dark
2.0 display very strange bitmaps on devices with 24 bits of color
depth. Release 2.0a of After Dark solves this problem. Contact
Berkeley Systems Technical Support at 1-800-877-5535 for this upgrade.
. Microsoft MediaPlayer
The Microsoft MediaPlayer application, when playing back Video for Windows
AVI files, has an option to play video clips at full screen. This option
bypasses Windows to force the VGA into a non-standard mode. Spectrum/24
will yield the display to the VGA while the clip is playing, but never
receives a signal when the clip is finished. Thus, your screen will
continue to display the final AVI frame forever, and your system will
appear to be hung. In fact, Windows is still running, and you should be
able to hit Alt-F4 and Enter until Windows exits back to DOS.
The interim solution is to only use full-screen mode when you are running
a VGA driver. Microsoft is aware of the problem and is working on a
permanent solution.
5. Compaq Prosignia with motherboard SCSI
------------------------------------------
There is a bug in the ROM BIOS for the on-board SCSI controller on all
Compaq Prosignia systems. This bug results in the upper half of one of
the 80486 32-bit registers (EAX) getting lost during a SCSI hardware
interrupt, which can occur at any time. This bug manifests itself as a
General Protection Fault in THUNVL.DRV when the mouse is being moved while
the screen is refreshing at the same time disk activity is going on.
Compaq is currently working on update to their ROM BIOS, and has a corrective
patch disk available through their technical support. Until you receive
that update, you can use the "CPQSCSI.COM" program which is installed in
the system\supermac subdirectory of your Windows directory by the Thunder/24
installation program. You need to include a line invoking CPQSCSI in your
AUTOEXEC.BAT file. You must inform CPQSCSI of the IRQ number that your
SCSI controller is using; you can find out the IRQ number by running your
EISA configuration utility. The default IRQ is 15; if this is the case
for you, include a line in your AUTOEXEC.BAT reading:
c:\windows\system\supermac\cpqscsi 15
This program takes up only a few bytes of memory, and saves and restores
all of the 32-bit registers around each SCSI hardware interrupt.
If you need assistance with this procedure, contact SuperMatch Technical